为研究机场可再生能源项目的布局规划,在总结机场用能的一般规律和能源规划的主要理论基础上,提出了“指标-决策-布局-评估”四位一体的规划方法。从机场自然资源条件、经济条件和环境条件3个维度选取了11个指标建立可再生能源机场适用性评估体系;在此基础上采用多目标决策法和Lingo模型对可再生能源项目规模进行定量决策,并针对不同规模机场设置了分布式、集中式和混合式3种可再生能源项目布局方式;最后从经济效益和环境效益两个方面对整体规划方案进行综合评估,形成了基于绿色低碳理念的、系统性的机场可再生能源规划布局方法。以北京首都国际机场可再生能源规划为实例对规划方法进行验证,结果显示该规划方法能够指导机场合理选择可再生能源项目,并能根据机场的自然资源条件和实际运行情况对可再生能源项目进行科学布局。
Based on the universal rule of airport energy utilization and the main theory of energy planning, a new planning method integrating indicators, decisions, layouts and evaluation was proposed to study the layout planning of airport renewable energy projects. Eleven indicators were selected from three dimensions which included the natural resource conditions, economic conditions and environmental conditions of the airport, to establish an assessment system for the suitability of airport renewable energy. On this basis, the multi-objective decision-making method and Lingo model were used to quantitatively decide the scale of a certain renewable energy project. Meanwhile, three layout methods including distributed layout, centralized layout and hybrid layout were proposed according to the different scales of airports. At last, the entire planning was comprehensively evaluated considering both economic and environmental benefits, and a systematic and low-carbon-based airport renewable energy planning system would come into being. The proposed method was validated by studying the renewable energy planning of Beijing Capital International Airport. The result shows that the planning method is able to guide the airport to choose a reasonable renewable energy project and make a scientific layout according to the natural resource conditions and running situation of the airport.
[1] International Council on Clean Transportation. CO2 emissions from commercial aviation, 2018[R]. Washington DC: International Council on Clean Transportation, 2019.
[2] Sergio O A, Maria M. Energy research in airports: A review[J]. Energies, 2016, 9(5): 349-368.
[3] 民航统计中心. 中国民航统计报告[EB/OL]. (2019-04-18)[2020-03-21].
[4] Barrett S B, DeVita P M, Whiteman A, et al. Renewable energy as an airport revenue source[R]// Airport Cooperative Research Program (ACRP) Report 141. Washington DC: Transportation Research Board, Federal Aviation Administration, 2015.
[5] 吉平,周孝信,宋云亭,等. 区域可再生能源规划模型述评与展望[J]. 电网技术,2013(8):2071-2079.
[6] 徐宝萍,徐稳龙. 低碳形势下的区域能源规划方法及实践[J]. 暖通空调,2012,42(12):10-16
[7] 宣蔚,郑炘. 低碳能源系统与城市规划一体化的理论构建[J]. 规划师,2014(11):82-86.
[8] Kumar A, Sah B, Singh A R, et al. A review of multi criteria decision making (MCDM) towards sustainable renewable energy development[J]. Renewable and Sustainable Energy Reviews, 2017, 67: 596-609.
[9] Apak S, Atay E, Tuncer G. Financial risk management in renewable energy sector: comparative analysis between the European Union and Turkey[J]. Procedia-Social and Behavioral Sciences, 2011, 24: 935-945.
[10] 代春艳,张希良,王恩创,等. 基于VIKOR多属性方法的可再生能源技术评价研究[J]. 科学决策,2012(1):65-76.
[11] Bhowmik, Chiranjib, Sumit, et al. Optimal green energy planning for sustainable development: A review[J]. Renewable and Sustainable Energy Reviews, 2017, 71: 796-813.
[12] Zangeneh A, Jadid S, Rahimi-Kian A. A fuzzy environmental-technical-economic model for distributed generation planning[J]. Energy, 2011, 36(5): 3437-3445.
[13] Xu B P, Zhou S X, Hao L. Approach and practices of district energy planning to achieve low carbon outcomes in China[J]. Energy Policy, 2015, 83: 109-122.
[14] Kalogirou S A. Applications of artificial neural-networks for energy systems[J]. Applied Energy, 2000, 6(1-2): 17-35.
[15] 司鹏飞,戎向阳,石利军,等. 机场航站楼能耗构成特征案例分析[J]. 暖通空调,2019,49(6):63-67.
[16] 杜勇. 绿色能源之首都机场能源中心[J]. 机场建设,2010(2):45-47.
[17] 李柯,何凡能. 中国陆地太阳能资源开发潜力区域分析[J]. 地理科学进展,2010,29(9):1049-1054.
[18] 李泽椿,朱蓉,何晓凤,等. 风能资源评估技术方法研究[J]. 气象学报,2007,65(5):708-717.
[19] 刘凯,王珊珊,孙颖,等. 北京地区地热资源特征与区划研究[J]. 中国地质,2017,44(6):1128-1139.
[20] 刘静,王慧婷,李莉,等. 广州白云国际机场航空垃圾焚烧处理方案探讨[J]. 环境工程,2012,30(S2):293-295.
[21] 周扬,吴文祥,胡莹,等. 江苏省可用太阳能资源潜力评估[J]. 可再生能源,2010,28(6):10-13.
[22] Kiyak E. A green transformation for anadolu airport terminal building[J]. European Journal of Sustainable Development, 2015, 4(2): 83-88.
[23] 北京市质量技术监督局. 地埋管地源热泵系统工程技术规范:DB11/T 1253—2015[S]. 北京:北京市质量技术监督局,2015.
[24] Moghavvemi M, Olatomiwa L, Mekhilef S, et al. Energy management strategies in hybrid renewable energy systems: A review[J]. Renewable and Sustainable Energy Reviews, 2016, 62: 821-835.
[25] 彭武元,陈思宇. 中国碳排放试点市场碳交易价格分析及预测[J]. 技术经济,2020,39(3):102-110.
[26] 刘亦文,胡宗义. 调整折标系数在我国节能降耗中的应用研究[J]. 统计与决策,2010(10):43-45.